Gossen Sixtomat flash Instrukcja Użytkownika Strona 12

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 20
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 11
12 GOSSEN Foto- und Lichtmeßtechnik GmbH
3.2.4 Contrast measurement
Select with the function buttons
Keep the measuring button depressed
while aiming the meter at various areas of the
subject. The analog aperture scale displays
the f-stop series between two extreme values,
and with the actual measured value flashing.
The first measured f-stop is displayed on the
left-hand side of the display (it remains dis-
played as a reference value (e.g. of a
grey card)).
After the measuring button is released, the
entire measured contrast range is displayed
on the analog aperture scale, and the last
measured value will cease to flash.
3.2.5 Aperture priority mode
Select with the function buttons
Set the desired aperture with the value but-
tons. The intermediate 1/10 stop values stored
from the last measurement appear when the
aperture is preset. These are invalid because
the valid 1/10th stops will only appear after the
next meter reading is taken.
Measure by pressing the meas. button
The measured shutter speed appears on the
right-hand digital display
Automatic adaptation of the aperture
in 1/10 stops to the measured shutter speed
Select other paired aperture/shutter values
with the value buttons
t
M
f
M
Przeglądanie stron 11
1 2 ... 7 8 9 10 11 12 13 14 15 16 17 18 19 20

Komentarze do niniejszej Instrukcji

Brak uwag